Super Box Unit
Temperature

content.product.temp-range

between -30°C en +18°C

Space

content.product.surface

from 6.06 m² to 51.27 m²

Super Box Unit
Capacity

content.product.storage

4 to 44 pallets

Super Box Unit
the ideal industrial cold store

Looking for a good-quality flexible solution for extra cold storage or freeze storage capacity? The Super Box Unit is the industrial freezer or fridge you are looking for. This mobile cold room is designed especially to offer flexible, high-quality solutions for your storage shortage. The Super Box Unit cold room is available for immediate rental. The container also complies with a range of standards, including HACCP, BRC and GMP. A mobile refrigerated container is the perfect replacement for standard cold storage.

Rent our cold rooms on a flexible basis

The major advantage of Dawsonrentals is that you can rent your refrigerated storage units rather than buying them. Your storage needs may vary, and our flexible solutions allow you to accommodate that variable demand.

Bakery Catering Chemical industry Flowers and seeds Fruit and vegetables Healthcare sector Meat, fish and poultry Pharmacy Seasonal industry Wholesale and logistics

The numerous advantages make the Super Box Units the ideal mobile cold storage solution. A few of the standard features and options are explained below.

Internal lighting

The Super Box Unit always includes internal lighting, at a light intensity of 300 lux per metre.

Verlichting

Hygienic, non-slip, resin floors

The floor of these industrial freezers is flat and has a non-slip coating, so you can easily and safely bring in a pallet or roll cage. The Super Box Unit also has a sloping corner along the 45° walls, so no dirt or insects can get into the seams. There is a drain in the floors.

Vloer

Data logger

A data logger is a standard feature in our Super Box Unit These devices make it easy to read out data on air temperature, when and how long doors were open, defrosting cycle, and any malfunctions.

Dataregistratieapparatuur

Strip curtain

This industrial freezer includes a strip curtain that keeps the cold inside, keeping the temperature inside the cold room separate from the outdoor temperature when the doors are open.

Koudegordijn

Internal light switch and man trap alarm

The Super Box Unit includes a light switch so the light can be turned on from inside the cold room. It also has a man trap alarm so employees can alert people outside if they are accidentally locked in. The alarm includes both acoustic and visual warning signals.

Interne lichtknop en insluitalarm

Door lock

The Super Box Unit is easy to open and has a convenient door lock.

Deurslot

content.optional.optional

  • content.optional.soundproofing-cap
  • content.optional.ramp
  • content.optional.internal-unlock
  • content.optional.linked-to-building
  • content.optional.frame
  • content.optional.humidifier
  • content.optional.redundant
  • content.optional.partition
  • content.optional.sliding-door
  • Quality and flexibility
  • Meet HACCP and BRC standards
  • Storage capacity from 4 to 44 pallets
  • Floor space from 6.06 m2 to 51.27 m2
  • Temperature range: between -30ºC and +18ºC
  • Hygienic, non-slip, flat floors
  • Internal lock
  • Internal light switch
  • Data registration devices
  • Temporary or permanent solution
  • Multiple door options available
  • 24/7 service
content.model.min-temp
-25°C
content.model.max-temp
+8°C
content.model.electric-connection
16 A
content.model.operating-voltage
380 V
content.model.refrigerant
R404a
content.model.phases
3 phases
content.model.length-ext
3,00 m
content.model.width-ext
2,40 m
content.model.height-ext
2,32 m
content.model.length-int
2,78 m
content.model.width-int
2,18 m
content.model.height-int
2,00 m
content.model.door-height
1,90 meter
content.model.door-width
89,5 meter
content.model.entry-threshold
25 cm
content.model.empty-weight
1.050 kg
content.model.floor-load
1.500 kg/m²
content.model.noise
50 dB
content.model.min-temp
-30°C
content.model.max-temp
+18°C
content.model.electric-connection
25 A
content.model.operating-voltage
380 V
content.model.refrigerant
R404a
content.model.phases
3 phases
content.model.length-ext
6,06 m
content.model.width-ext
2,86 m
content.model.height-ext
2,70 m
content.model.length-int
5,12 m
content.model.width-int
2,64 m
content.model.height-int
2,26 m
content.model.door-height
2,14 m
content.model.door-width
1,85 m
content.model.entry-threshold
30 cm
content.model.empty-weight
3.150 kg
content.model.floor-load
1.500 kg/m²
content.model.noise
54 dB
content.model.min-temp
-30°C
content.model.max-temp
+18°C
content.model.electric-connection
25 A
content.model.operating-voltage
380 V
content.model.refrigerant
R404a
content.model.phases
3 phases
content.model.length-ext
6,06 m
content.model.width-ext
3,80 m
content.model.height-ext
2,70 m
content.model.length-int
5,12 m
content.model.width-int
3,58 m
content.model.height-int
2,26 m
content.model.door-height
2,14 m
content.model.door-width
1,85 m
content.model.entry-threshold
30 cm
content.model.empty-weight
3.850 kg
content.model.floor-load
1.500 kg/m²
content.model.noise
54 dB
content.model.min-temp
-30°C
content.model.max-temp
+18°C
content.model.electric-connection
25 A
content.model.operating-voltage
380 V
content.model.refrigerant
R404a
content.model.phases
3 phases
content.model.length-ext
9,25 m
content.model.width-ext
2,89 m
content.model.height-ext
2,70 m
content.model.length-int
8,33 m
content.model.width-int
2,67 m
content.model.height-int
2,26 m
content.model.door-height
2,14 m
content.model.door-width
1,85 m
content.model.entry-threshold
30 cm
content.model.empty-weight
4.250 kg
content.model.floor-load
1.500 kg/m²
content.model.noise
54 dB
content.model.min-temp
-25°C
content.model.max-temp
+18°C
content.model.electric-connection
25 A
content.model.operating-voltage
380 V
content.model.refrigerant
R404a
content.model.phases
3 phases
content.model.length-ext
8,83 m
content.model.width-ext
3,80 m
content.model.height-ext
2,70 m
content.model.length-int
7,90 m
content.model.width-int
3,58 m
content.model.height-int
2,26 m
content.model.door-height
2,14 m
content.model.door-width
1,85 m
content.model.entry-threshold
30 cm
content.model.empty-weight
5.100 kg
content.model.floor-load
1.500 kg/m²
content.model.noise
54 dB
content.model.min-temp
-25°C
content.model.max-temp
+18°C
content.model.electric-connection
25 A
content.model.operating-voltage
380 V
content.model.refrigerant
R404a
content.model.phases
3 phases
content.model.length-ext
12.20 m
content.model.width-ext
2,89 m
content.model.height-ext
2,70m
content.model.length-int
11,26 m
content.model.width-int
2,67 m
content.model.height-int
2,26 m
content.model.door-height
2,14 m
content.model.door-width
1,85 m
content.model.entry-threshold
30 cm
content.model.empty-weight
4.700 kg
content.model.floor-load
1.500 kg/m²
content.model.noise
54 dB
content.model.min-temp
-25°C
content.model.max-temp
+18°C
content.model.electric-connection
25 A
content.model.operating-voltage
380 V
content.model.refrigerant
R404a
content.model.phases
3 phases
content.model.length-ext
14,43 m
content.model.width-ext
2,89 m
content.model.height-ext
2,70 m
content.model.length-int
13,50 m
content.model.width-int
2,67 m
content.model.height-int
2,26 m
content.model.door-height
2,14 m
content.model.door-width
1,85 m
content.model.entry-threshold
30 cm
content.model.empty-weight
5.175 kg
content.model.floor-load
1.500 kg/m²
content.model.noise
54 dB
content.model.min-temp
-25°C
content.model.max-temp
+18°C
content.model.electric-connection
25 A
content.model.operating-voltage
380 V
content.model.refrigerant
R404a
content.model.phases
3 phases
content.model.length-ext
12,20 m
content.model.width-ext
3,80 m
content.model.height-ext
2,70 m
content.model.length-int
11,26 m
content.model.width-int
3,58 m
content.model.height-int
2,26 m
content.model.door-height
2,14 m
content.model.door-width
1,85 m
content.model.entry-threshold
30 cm
content.model.empty-weight
5.650 kg
content.model.floor-load
1.500 kg/m²
content.model.noise
54 dB
content.model.min-temp
-25°C
content.model.max-temp
+18°C
content.model.electric-connection
32 A
content.model.operating-voltage
380 V
content.model.refrigerant
R404a
content.model.phases
3 phases
content.model.length-ext
15,24 m
content.model.width-ext
3,80 m
content.model.height-ext
2,70 m
content.model.length-int
14,31 m
content.model.width-int
3,58 m
content.model.height-int
2,26 m
content.model.door-height
2,14 m
content.model.door-width
1,85 m
content.model.entry-threshold
30 cm
content.model.empty-weight
6.950 kg
content.model.floor-load
1.500 kg/m²
content.model.noise
56 dB
Super Box Unit
Super Box Unit
Super Box Unit
Super Box Unit
Super Box Unit
Super Box Unit
Super Box Unit
Super Box Unit